Logo-jrhs
J Res Health Sci. 2023;23(1): e00576.
doi: 10.34172/jrhs.2023.111
PMID: 37571947
PMCID: PMC10422144
Scopus ID: 85153960617
  Abstract View: 635
  PDF Download: 275
  Full Text View: 211

Original Article

Evaluation of Seasonal Variation on the Health Risks Using the Quantitative Microbial Risk Assessment Approach in a Wastewater Treatment Plant in Hamadan, Iran

Melika Hooshmandi, Ashraf Mazaheri Tehrani, Majid Habibi Mohraz, Mostafa Leili, Mohammad Javad Assari*
*Corresponding Author: Email: Asari@umsha.ac.ir

Abstract

Background: Wastewater treatment plants (WWTPs) are a source of airborne bacterial contamination that can pose health risks to staff. The aim of this study was to evaluate seasonal variations in the health risks of exposure to Staphylococcus aureus bioaerosols using the quantitative microbial risk assessment (QMRA) approach in a WWTP in Hamadan, Iran.

Study Design: This was a descriptive cross-sectional study.

Methods: This study determined the emission concentrations of S. aureus bioaerosols in summer and winter. Then, the health risks of three exposure scenarios (the worker, field engineer, and laboratory technician) were evaluated using the QMRA approach. The bioaerosol samples were collected every 12 days in both summer and winter of 2021 with a nutrient agar using a single-stage cascade impactor (Quick Take 30, SKC Inc.) in both outdoor and indoor environments.

Results: The results demonstrated that in both seasons, S. aureus bioaerosol concentrations in outdoor and indoor environments were below the standard established by the American Conference of Governmental Industrial Hygienists (500 CFU/m3 ). While in summer, the annual infection risks and the disease burden for the three exposure scenarios in both outdoor and indoor environments were higher than the United States Environmental Protection Agency (≤10-4 pppy) and the World Health Organization (WHO) (≤10-6 DALYs pppy-1) benchmarks, respectively.

Conclusion: The findings provided high health risks for staff in the three exposure scenarios of an indoor environment, which should not be ignored, as well as emphasizing the use of the QMRA approach to estimate health risks caused by occupational exposure to bioaerosols and taking executive measures to protect staff working in the WWTPs.

First Name
Last Name
Email Address
Comments
Security code


Abstract View: 636

Your browser does not support the canvas element.


PDF Download: 275

Your browser does not support the canvas element.


Full Text View: 211

Your browser does not support the canvas element.

Submitted: 20 Nov 2022
Revision: 08 Apr 2023
ePublished: 08 Apr 2023
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)